Hope Deepblue Air Conditioning Manufacture Corp., Ltd.
News

news

  • The Working Principle of Automatic Purge Device

    The Working Principle of Automatic Purge Device

    The Working Principle of Automatic Purge Device In Hope Deeeblue we commonly used purging devices are mechanical vacuum purging device and automatic purging device.The working principle is: Utilizing the jet impact of the high-pressure liquid stream dis...
    Read more
  • Why Should Li2MoO4 Be Added to LiBr Absorption Units?

    Why Should Li2MoO4 Be Added to LiBr Absorption Units?

    Why Should Li2MoO4 Be Added to LiBr Absorption Units? The Role of Li₂MoO₄ in LiBr Absorption Units As a leading manufacturer of LiBr absorption chillers and heat pumps, Hope Deepblue emphasizes the significance of the LiBr solution as the primary...
    Read more
  • The Importance of Cooling Water for LiBr Absorption Chiller

    The Importance of Cooling Water for LiBr Absorption Chiller

    The Importance of Cooling Water for LiBr Absorption Chiller. The main product of Hope Deepblue are LiBr absorption chiller and heat pump, and when the  LiBr absorption unit operation. cooling water as an essential part in our unit 1. The effect of cooli...
    Read more
  • The Role of Isooctanol in LiBr Absorption Unit.

    The Role of Isooctanol in LiBr Absorption Unit.

    The Role of Isooctanol in LiBr Absorption Unit. The Role of Surfactants in LiBr Absorption Units While the LiBr solution is indeed the "lifeblood" of LiBr absorption chillers and heat pumps, its performance can be significantly enhanced by the addition ...
    Read more
  • What is an Automatic De-crystallization Device?

    What is an Automatic De-crystallization Device?

    What is an Automatic De-crystallization Device? What is Crystallization in LiBr Absorption Units? Crystallization in LiBr absorption chillers and heat pumps refers to the process where the LiBr solution (lithium bromide) transitions from a liquid state ...
    Read more
  • Types of Heat Exchangers

    Types of Heat Exchangers

    Types of Heat Exchangers Differences Between Plate Heat Exchangers and Shell-and-Tube Heat Exchangers Both plate heat exchangers and shell-and-tube heat exchangers are integral components in Hope Deepblue's LiBr absorption chillers and heat pumps, each...
    Read more
  • What Are the Refrigerant, Surfactant, and Corrosion Inhibitor for LiBr Absorption Chiller?

    What Are the Refrigerant, Surfactant, and Corrosion Inhibitor for LiBr Absorption Chiller?

    What Are the Refrigerant, Surfactant, and Corrosion Inhibitor for LiBr Absorption Chiller? Hope Deepblue is the largest manufacturer of refrigeration and heating equipment in southwest China. The main products are LiBr absorption chiller and heat pump. ...
    Read more
  • Cause of damage of condensate heat exchange plate.

    Cause of damage of condensate heat exchange plate.

    Cause of Damage of Condensate Heat Exchange Plate Hope Deepblue is the largest manufacturer of refrigeration and heating equipment in Southwest China, specializing in LiBr absorption chillers and heat pumps. These units are designed for cooling u...
    Read more
  • Factors Affecting Corrosion of Metallic Materials by LiBr Solution

    Factors Affecting Corrosion of Metallic Materials by LiBr Solution

    Factors Affecting Corrosion of Metallic Materials by LiBr Solution LiBr solution plays a crucial role in the operation of Hope Deepblue's LiBr absorption chillers and heat pumps, as it is integral to the heat exchange and refrigeration process. H...
    Read more
  • Factors Influencing the Cooling Capacity of LiBr Absorption Chiller

    Factors Influencing the Cooling Capacity of LiBr Absorption Chiller

    Factors Affecting the Cooling Capacity of LiBr Absorption Chiller LiBr absorption chillers primarily use waste heat for refrigeration, but over time, they may experience a reduction in cooling capacity, which can fail to meet required demands. As expert...
    Read more
  • Why the Evaporator Adopts Sprayer and the Absorber Adopts Spray Plate?

    Why the Evaporator Adopts Sprayer and the Absorber Adopts Spray Plate?

    Why the Evaporator Adopts Sprayer and the Absorber Adopts Spray Plate? In Hope Deepblue's LiBr absorption chillers, refrigerant water is kept clean to minimize the risk of blockages in the system. The refrigerant water is transferred by a pump...
    Read more
  • The Regular Inspection and Maintenance of LiBr Absorption Unit

    The Regular Inspection and Maintenance of LiBr Absorption Unit

    The regular inspection and maintenance of LiBr absorption unit The lifespan of Hope Deepblue LiBr absorption chillers is approximately 20-25 years. To ensure the stable and efficient operation of the unit throughout its lifespan, regular and meti...
    Read more