Hope Deepblue Air Conditioning Manufacture Corp., Ltd.
Hot Water Absorption Chiller

Products

Hot Water Absorption Chiller

General Description:


Product Detail

Product Tags

CHILLER FEATURES

1. Industrial water chiller manufacturers-Hope Deepblue Interlock mechanical & electrical anti-freezing system: multi anti-freezing protection
The coordinated anti-freezing system features following merits: a lowered primary sprayer design for the evaporator, an interlock mechanism which links the secondary sprayer of evaporator with the supply of chilled water and cooling water, a pipe blockage prevention device, a two-hierachy chilled water flow switch, an interlock mechanism designed for the chilled water pump and cooling water pump. Six levels anti freezing design ensures timely detection of break, underflow, low temperature of chilled water, automatic actions will be taken to prevent tube freezing.

2. Industrial water chiller manufacturers-Hope Deepblue Auto purge system combining muti-ejector&fall-head technology: speedy vacuum purging and high vacuum degree maintenance
This is a new, high efficiency automatic air purge system. The ejector functions as a small air extraction pump. DEEPBLUE automatic air purge system adopts multiple ejectors to increase the air extraction and purge rate of chiller. Water head design can help to evaluate vacuum limits and maintain a high vacuum degree. The design with features rapidly and highness can provide a high vacuum degree for every part of chiller at any time. Therefore, oxygen corrosion is precluded, service life time is prolonged and optimal operating status is maintained for chiller.

Multi Energy LiBr Absorption Chiller

3. Industrial water chiller manufacturers-Hope Deepblue Simple and reliable system pipe design: easy operation and reliable quality
Maintainable structure design: spray plate in absorber and spray nozzle in evaporator are replaceable. Ensure capacity will not drop in lifespan. No solution regulation valve, refrigerant spray valve and high pressure refrigerant valve, so the leakage points are less, and unit can keep stable operation without manual regulation.

4. Industrial water chiller manufacturers-Hope Deepblue Automatic anti-crystallization system combining potential difference-based dilution and crystal dissolution: eliminate crystallization
A self-contained temperature & potential difference detection system enables chiller to monitor excessively high concentration of the concentrated solution. On one hand upon detecting an overly high concentration the chiller automatically feeds refrigerant water to concentrated solution for dilution, on the other hand, the chiller utilizes HT LiBr solution in generator to heat concentrated solution to a higher temperature. In the event of a sudden power failure or abnormal shutdown, potential difference-based dilution system will start rapidly to dilute LiBr solution and to ensure rapid dilution after power supply recovers.

hot water absorption chiller

5. Industrial water chiller manufacturers-Hope Deepblue Tube broken alarm device

When the heat exchange tubes broke in hot water absorption chiller at abnormal condition, control system send out an alarm to remind operator to take actions, reduce damage.

6.Self-adaptive refrigerant storage unit: improving part load performance and shortening startup/shutdown time.
The refrigerant water storage capacity can be automatically adjusted according to external load changes, particularly when the hot water absorption chiller works under partial load. The adoption of refrigerant storage device can shorten startup/shutdown time substantially and reduce idle work.

7.Economizer: energy output boosting
Isooctanol with a conventional chemical structure as an energy boosting agent added to LiBr solution, is normally an insoluble chemical that has only a limited energy boosting effect. The economizer can prepare mixture of isooctanol and LiBr solution in a special way to guide isooctanol into generation and absorption process, therefore enhancing energy boosting effect, effectively reducing energy consumption and realizing energy efficiency.

8.Integral sintered sight glass: a powerful guarantee for high vacuum performance
The leakage rate of the whole unit is lower than 2.03X10-9 Pa.m3 /S , Which is 3 grade higher than national standard, can ensure unit's lifespan.
Unique surface treatment for heat exchange tubes: high performance in heat exchanging & less energy consumption
The evaporator and absorber have been hydrophilic treated to ensure even liquid film distribution on tube surface. This design can improve heat exchange effect and lower energy consumption.

9.Li2MoO4 Corrosion inhibitor: an environment –friendly corrosion inhibitor
Lithium Molybate (Li2MoO4), an environment-friendly corrosion inhibitor, is used to replace Li2CrO4 (Containing heavy metals) during the preparation of LiBr solution.

10.Frequency control operation: an energy-saving technology
Chiller can adjust its operation automatically and maintain optimal working according to different cooling load.

11.Plate heat exchanger: saving more than 10% energy
A stainless corrugated steel plate heat exchanger is adopted. This type of plate heat exchanger has a very sound effect, a high heat recovery rate and remarkable energy saving performance. Meanwhile, the stainless steel plate has a service life of over 20 years.

ARTIFICIAL INTELLIGENT CONTROL SYSTEM AI (V5.0)

1.Fully-automatic control functions
The control system (AI, V5.0) is featured by powerful and complete functions, such as one-key start up/ shutdown, timing on/off, mature safety protection system, multiple automatic adjustment, system interlock, expert system, human machine dialogue(multi languages), building automation interfaces, etc.

2.Complete chiller abnormality self-diagnosis and protection function.
The control system (AI, V5.0) features 34 abnormality self-diagnosis & protection functions. Automatic steps will be taken by system according to level of an abnormality. This is intended to prevent accidents, minimize human labor and ensures a sustained, safe and stable operation of hot water absorption  chiller.

3.Unique load adjustment function
The control system (AI, V5.0) has a unique load adjustment function, which enables automatic adjustment of hot water absorption chiller output according to actual load. This function not only helps to reduce startup/shutdown time and dilution time, but also contributes to less idle work and energy consumption.

hot water absorption chiller
Hot water absorption chiller

4.Unique solution circulation volume control technology
The control system (AI, V5.0) employs an innovative ternary control technology to adjust circulated solution volume. Traditionally, only parameters of generator liquid level are used to control of solution circulation volume. This new technology combines merits of concentration & temperature of concentrated solution and liquid level in generator. Meanwhile, an advanced frequency–variable control technology is applied to solution pump to enable chiller to achieve an optimal circulated solution volume. This technology improves operating efficiency and reduces start-up time and energy consumption.

5.Cooling water temperature control technology
The control system (AI, V5.0) can control and adapt heat source input according to cooling water inlet temperature changes. By maintaining cooling water inlet temperature within 15-34 ℃, chiller operate safely and efficiently.

6.Solution concentration control technology
The control system (AI, V5.0) uses a unique concentration control technology to enable real-time monitoring/control of concentration and volume of concentrated solution as well as heat source input. This system can maintain chiller under safe and stable at high concentration condition, improve chiller operating efficiency and prevent crystallization.

7.Intelligent automatic air extraction function
The control system (AI, V5.0) can realize real-time monitoring of vacuum condition and purge out the non-condensable air automatically.

hot water absorption chiller

8.Unique dilution stop control
This control system (AI, V5.0) can control operation time of different pumps required for dilution operation, according to concentrated solution concentration, ambient temperature and remaining refrigerant water volume. Therefore, an optimal concentration can be maintained for the chiller after shutdown. Crystallization is precluded and chiller re-start time is shortened.

9.Working parameter management system
Through interface of this control system (AI, V5.0), operator can perform any of following operations for 12 critical parameters relating to chiller performance: real-time display, correction, setting. Records can be kept for historical operation events.

10.Chiller fault management system
If any prompt of occasional fault is displayed on operation interface, this control system(AI, V5.0) can locate and detail fault, propose a solution or trouble shooting guidance. Classification and statistical analyses of historical faults can be conducted to facilitate maintenance service provided by operator

11.Remote Operation & Maintenance System
Deepblue Remote Monitoring Center collects the data of the units distributed by Deepblue around the world. Through the classification, statistics, and analysis of real-time data, it displays in the form of reports, curves, and histograms to achieve an overall overview of equipment operating status and fault information control. Through a series of collection, calculation , control, alarm, early warning, equipment ledger, equipment operation and maintenance information and other functions, as well as customized special analysis and display functions, the remote operation, maintenance, and management needs of the unit are finally realized. The authorized client can browse the WEB or APP, which is convenient and fast.

NOMINAL PARAMETER

Single Stage Hot Water Absorption Chiller Parameter

Model RXZ(95/85)- 35 58 93 116 145 174 233 291 349 465 582 698 756
Cooling capacity kW 350 580 930 1160 1450 1740 2330 2910 3490 4650 5820 6980 7560
10kCal/h 30 50 80 100 125 150 200 250 300 400 500 600 650
USRT 99 165 265 331 413 496 661 827 992 1323 1653 1984 2152
Chilled
water
Inlet/outlet temp. 12→7
Flow rate m3/h 60 100 160 200 250 300 400 500 600 800 1000 1200 1300
Pressure drop kPa 70 80 80 90 90 80 80 80 60 60 70 80 80
Joint connection DN(mm) 100 125 150 150 200 250 250 250 250 300 350 400 400
Cooling
water
Inlet/outlet temp. 32→38
Flow rate m3/h 113 188 300 375 469 563 750 938 1125 1500 1875 2250 2438
Pressure drop kPa 65 70 70 75 75 80 80 80 70 70 80 80 80
Joint connection DN(mm) 125 150 200 250 250 300 350 350 350 400 450 500 500
Hot water Inlet/outlet temp. 95→85
Flow rate m3/h 38 63 100 125 156 188 250 313 375 500 625 750 813
Pressure drop kPa 76 90 90 90 90 95 95 95 75 75 90 90 90
Joint connection DN(mm) 80 100 125 150 150 200 250 250 250 300 300 300 300
Power Demand kW 2.8 3 3.8 4.2 4.4 5.4 6.4 7.4 7.7 8.7 12.2 14.2 15.2
Dimension Length mm 3100 3100 4120 4860 4860 5860 5890 5920 6920 6920 7980 8980 8980
Width mm 1400 1450 1500 1580 1710 1710 1930 2080 2080 2850 2920 3350 3420
Height mm 2340 2450 2810 2980 3180 3180 3490 3690 3720 3850 3940 4050 4210
Operation weight t 6.3 8.4 11.1 14 17 18.9 26.6 31.8 40 46.2 58.2 65 70.2
Shipment weight t 5.2 7.1 9.3 11.5 14.2 15.6 20.8 24.9 27.2 38.6 47.8 55.4 59.8
Cooling water inlet temp. range:15℃-34℃, minimum chilled water outlet temp. -2℃.
Cooling capacity regulation range 10%~100%.
Chilled water, cooling water and hot water fouling factor:0.086m2•K/kW.
Chilled water, cooling water and hot water maximum working pressure:0.8MPa.
Power type: 3Ph/380V/50Hz (or customized).
Chilled water flow adjustable range 60%-120%, cooling water flow adjustable range 50%-120%
Hope Deepblue reserves the right of interpretation,the parameters maybe amended at final design.

Double Phase Hot Water Absorption Chiller Parameter

Model RXZ(120/68)- 35 58 93 116 145 174 233 291 349 465 582 698 756
Cooling capacity kW 350 580 930 1160 1450 1740 2330 2910 3490 4650 5820 6980 7560
104 kCal/h 30 50 80 100 125 150 200 250 300 400 500 600 650
USRT 99 165 265 331 413 496 661 827 992 1323 1653 1984 2152
Chilled
water
Inlet/outlet temp. 12→7
Flow rate m3/h 60 100 160 200 250 300 400 500 600 800 1000 1200 1300
Pressure drop kPa 60 60 70 65 65 65 60 60 60 90 90 120 120
Joint connection DN(mm) 100 125 150 150 200 250 250 250 250 300 350 400 400
Cooling
water
Inlet/outlet temp. 32→38
Flow rate m3/h 113 188 300 375 469 563 750 938 1125 1500 1875 2250 2438
Pressure drop kPa 65 70 70 75 75 80 80 80 70 70 80 80 80
Joint connection DN(mm) 125 150 200 250 250 300 350 350 350 400 450 500 500
Hot water Inlet/outlet temp. 120→68
Flow rate m3/h 7 12 19 24 30 36 48 60 72 96 120 144 156
Power Demand kW 3.9 4.1 5 5.4 6 7 8.4 9.4 9.7 11.7 16.2 17.8 17.8
Dimension Length mm 4105 4105 5110 5890 5890 6740 6740 6820 7400 7400 8720 9670 9690
Width mm 1775 1890 2180 2244 2370 2560 2610 2680 3220 3400 3510 3590 3680
Height mm 2290 2420 2940 3160 3180 3240 3280 3320 3480 3560 3610 3780 3820
Operation weight t 7.4 9.7 15.2 18.4 21.2 23.8 29.1 38.6 44.2 52.8 69.2 80 85
Shipment weight t 6.8 8.8 13.8 16.1 18.6 21.2 25.8 34.6 39.2 46.2 58 67 71.2
Cooling water inlet temp. range:15℃-34℃, minimum chilled water outlet temp. 5℃.
Cooling capacity regulation range 20%~100%.
Chilled water, cooling water and hot water fouling factor:0.086m2•K/kW.
Chilled water, cooling water and hot water maximum working pressure:0.8MPa.
Power type: 3Ph/380V/50Hz (or customized)
Chilled water flow adjustable range 60%-120%, cooling water flow adjustable range 50%-120%
Hope Deepblue reserves the right of interpretation,the parameters maybe amended at final design.

MODEL SELECTION

Chilled Water Outlet Temperature
Besides the specified Chilled water outlet temperature of a standard chiller, other outlet temperature values (min -2℃) may also be selected.

Pressure Bearing Requirements
The design pressure bearing standard capacity of the Chilled water/cooling water system of the chiller is 0.8MPa. If the actual pressure of the water system exceeds this standard value, a HP-type chiller should be used.

Unit QTY
If more than one unit is used, the unit's QTY should be determined by comprehensive consideration of max load, partial load, maintenance period as well as machine room's size.

Control Mode
The Hot water absorption chiller is supported by an Al (artificial intelligence) control system that enables automatic operation. Meanwhile, there are a number of options available for the customers, such as control interfaces for the Chilled water pump, cooling water pump, cooling tower fan & buildings, centralized control system and internet access.

hot water absorption chiller

  • Previous:
  • Next:

  • Write your message here and send it to us